{"id":519457,"date":"2025-12-11T11:22:45","date_gmt":"2025-12-11T16:22:45","guid":{"rendered":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/"},"modified":"2025-12-11T11:22:45","modified_gmt":"2025-12-11T16:22:45","slug":"dtc-u0517-invalid-data-received-from-door-switch-b","status":"publish","type":"post","link":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/","title":{"rendered":"U0517 Code Symptoms, Causes, Diagnosis &#038; Repair &#038; Reprogramming Guide"},"content":{"rendered":"<div class=\"container\">\n<section class=\"hero\">\n<div class=\"code-badge\">U0517<\/div>\n<h1>U0517 Code Symptoms, Causes, Diagnosis &amp; Repair &amp; Reprogramming Guide<\/h1>\n<p class=\"hero-subtitle\">\n<\/section>\n<div class=\"quick-summary\">\n<h2>Quick Summary<\/h2>\n<ul>\n<li>U0517 means the Body Control Module (BCM) received invalid data from Door Switch B. <\/li>\n<li>Drivers notice door\u2011lock, interior\u2011lighting, or power\u2011window functions that act erratically or stop working. <\/li>\n<li>Most causes are a bad switch, damaged wiring, or BCM communication glitches. <\/li>\n<li>A scan\u2011tool, wiring continuity test, and switch voltage check usually isolate the fault. <\/li>\n<li>Replacement of the BCM is rarely needed; when it is, Flagship One provides VIN\u2011matched, pre\u2011programmed units. <\/li>\n<\/ul>\n<\/div>\n<h3>U0517 Code Symptoms \u2014 How to Diagnose and Resolve the Issue <\/h3>\n<p>Drivers typically first notice that the vehicle\u2019s door\u2011lock or unlock command does not respond as expected. The driver\u2011side power\u2011window may refuse to move, interior illumination can stay on or stay off, and the BCM\u2011related warning lamp (often a \u201cBCM\u201d or \u201cBody\u201d icon) may flash or stay illuminated on the instrument cluster. In some cases the vehicle will lock or unlock only on one side, or the \u201clock\u2011all\u201d button on the key fob will have no effect. Because the BCM governs multiple body\u2011related circuits, a single fault can produce several seemingly unrelated symptoms.<\/p>\n<h2>Symptoms <\/h2>\n<ul>\n<li><strong>Door\u2011lock\/unlock failure on the side equipped with Door Switch B<\/strong> \u2013 the driver\u2011side lock may not engage, or the unlock command may be ignored. <\/li>\n<li><strong>Interior\u2011lighting anomalies<\/strong> \u2013 dome light stays on after the doors are closed, or fails to turn on when a door is opened. <\/li>\n<li><strong>Power\u2011window irregularities<\/strong> \u2013 the driver\u2011side window may not move, or moves only intermittently. <\/li>\n<li><strong>BCM warning indicator<\/strong> \u2013 a dedicated BCM icon or a generic \u201cmalfunction indicator lamp\u201d appears on the dash. <\/li>\n<li><strong>Key\u2011fob lock\u2011all command ineffective<\/strong> \u2013 the vehicle does not respond to the remote\u2019s lock or unlock button. <\/li>\n<\/ul>\n<p>These signs appear together because the BCM relies on the signal from Door Switch B to coordinate the related circuits. When the data is corrupted or missing, the BCM disables the affected functions to protect the vehicle\u2019s electrical system.<\/p>\n<h2>Why This Happens <\/h2>\n<h3>Faulty Door Switch B <\/h3>\n<p>Door Switch B is a microswitch mounted in the driver\u2011side door jamb. Internal contact wear, corrosion, or physical damage can cause the switch to send voltage spikes, open\u2011circuit signals, or no signal at all. The BCM interprets these irregularities as \u201cinvalid data\u201d and logs U0517.<\/p>\n<h3>Wiring or Connector Problems <\/h3>\n<p>The harness that carries the switch signal runs through the door hinge and is subject to flexing, moisture ingress, and abrasion. A broken conductor, corroded pin, or loose connector can introduce resistance or intermittent continuity, producing spurious voltage readings that the BCM flags as invalid.<\/p>\n<h3>BCM Communication Fault <\/h3>\n<p>The BCM communicates with the Door Switch B via a CAN\u2011bus or LIN\u2011bus network. A corrupted CAN frame, a short to ground, or a failing BCM transceiver can distort the data packet, leading the module to reject the information and store U0517.<\/p>\n<h3>Software or Calibration Issues <\/h3>\n<p>Occasionally, a recent re\u2011programming of the BCM or a software update may leave the module\u2019s lookup table for Door Switch B mismatched to the hardware. In such cases the module reads correct voltages but still classifies them as invalid because the expected parameters are out of range.<\/p>\n<h2>Diagnostic and Repair Procedures <\/h2>\n<ol>\n<li><strong>Scan for Codes<\/strong> \u2013 Connect a dealer\u2011level scan tool to read U0517 and any accompanying BCM codes (e.g., U0100, U0121). Note whether the BCM is in \u201cdiagnostic mode\u201d or has entered a \u201climp\u2011home\u201d state.\n<\/li>\n<li><strong>Visual Inspection<\/strong> \u2013 Open the driver\u2011side door panel. Check the Door Switch B for signs of corrosion, broken mounting tabs, or physical damage. Inspect the wiring harness for cracked insulation, pinched sections, or water intrusion.\n<\/li>\n<li><strong>Continuity Test<\/strong> \u2013 With the ignition off, disconnect the Door Switch B connector. Use a multimeter to verify continuity between the harness pins at the door latch and the BCM connector. A resistance reading above 1 \u03a9 usually indicates a wiring fault.\n<\/li>\n<li><strong>Voltage Verification<\/strong> \u2013 Reconnect the switch, turn the ignition to the \u201cON\u201d position, and measure the voltage at the switch\u2019s signal wire. A healthy switch typically shows 0 V (open) when the door is closed and 12 V (or a pulsed signal on CAN\/LIN) when the door is opened. Fluctuating or out\u2011of\u2011range voltages confirm an invalid data condition.\n<\/li>\n<li><strong>Connector Cleaning<\/strong> \u2013 If resistance or voltage anomalies are found, clean the connector pins with electrical contact cleaner and reseat them. Re\u2011test the voltage and continuity.\n<\/li>\n<li><strong>Switch Replacement<\/strong> \u2013 When the switch fails the voltage test (stays at 0 V, stays at 12 V, or shows intermittent spikes), replace Door Switch B. The replacement part must match the vehicle\u2019s VIN\u2011specific part number; install, route the harness correctly, and retest.\n<\/li>\n<li><strong>BCM Communication Check<\/strong> \u2013 If the switch and wiring are sound, perform a CAN\u2011bus diagnostic using the scan tool. Look for \u201cbus off\u201d errors or high error counters. A corrupted bus may require BCM re\u2011programming or, in rare cases, replacement.\n<\/li>\n<li><strong>Re\u2011programming<\/strong> \u2013 When a software mismatch is suspected, update the BCM with the latest factory calibration. Use a tool that can write the correct VIN\u2011linked firmware; this ensures the module interprets Door Switch B data correctly.\n<\/li>\n<li><strong>Clear Codes and Test Drive<\/strong> \u2013 After repairs, clear all stored codes, then perform a functional test: lock\/unlock with the key fob, open\/close the driver\u2019s door, and operate the driver\u2011side power window. Verify that the BCM warning lamp remains off.\n<\/li>\n<\/ol>\n<p><strong>Typical costs<\/strong> \u2013 Door Switch B parts range from $30\u2011$70. Labor for removal and installation is usually 0.5\u20111 hour ($80\u2011$120). Wiring repairs average $100\u2011$150 for connector work. BCM re\u2011programming, when required, is $120\u2011$180 plus labor. <\/p>\n<h2>When Replacement Makes Sense <\/h2>\n<div class=\"flagship-logo-section\">\n<a href=\"https:\/\/www.fs1inc.com\/\" rel=\"noopener noreferrer\" target=\"_blank\"><br \/>\n<img decoding=\"async\" alt=\"Flagship One\" class=\"flagship-logo\" src=\"https:\/\/www.fs1inc.com\/blog\/wp-content\/uploads\/2025\/12\/fs1inc_logo2-scaled.jpg\"\/><br \/>\n<\/a>\n<\/div>\n<p>If the BCM repeatedly logs U0517 after multiple switch and wiring repairs, or if the module fails the built\u2011in self\u2011test during the CAN\u2011bus diagnostic, replacement becomes the more reliable solution. Modern control modules are complex, integrating security, immobilizer, and body\u2011function networks. Choosing a replacement isn\u2019t only about the hardware\u2014it\u2019s about correct programming and compatibility. <\/p>\n<p><strong>Flagship One<\/strong> specializes in VIN\u2011matched control modules, providing a plug\u2011and\u2011drive solution backed by a comprehensive warranty. Replacement units are matched to the vehicle\u2019s production date and software version, then pre\u2011programmed before shipment, eliminating the need for dealer\u2011only re\u2011coding. This approach minimizes downtime and ensures the new BCM communicates flawlessly with Door Switch B and the rest of the vehicle\u2019s network. <\/p>\n<h2>Preventive Maintenance <\/h2>\n<ul>\n<li><strong>Lubricate Door Switches<\/strong> \u2013 Apply a light dielectric grease to the switch\u2019s moving contacts during routine door\u2011latch service to prevent corrosion. <\/li>\n<li><strong>Protect Wiring Harnesses<\/strong> \u2013 When reinstalling the door panel, verify that the harness is routed away from sharp edges and that the rubber boot is seated fully to keep moisture out. <\/li>\n<li><strong>Regular Inspection<\/strong> \u2013 During scheduled maintenance (every 12,000 mi or 12 months), have a technician check the door\u2011switch operation and scan for pending BCM codes. Early detection prevents intermittent faults from becoming permanent failures. <\/li>\n<li><strong>Software Updates<\/strong> \u2013 Keep the BCM firmware current by applying manufacturer\u2011issued updates, especially after a major recall or service bulletin that addresses body\u2011control communication.<\/li>\n<\/ul>\n<div class=\"info-section\">\n<p><strong>Service Recommendation:<\/strong> Most issues related to this fault are diagnosed and corrected through inspection, wiring repair, and calibration rather than module replacement. For modules not typically replaced through aftermarket suppliers, diagnosis and repair should be performed by a certified automotive technician with access to factory service information and tooling.<\/p>\n<\/div>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Door lock\/unlock fails, warning light on vehicle? Invalid data from Door Switch B can shut off BCM functions\u2014scan, test the switch, reprogram or replace.<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"closed","sticky":false,"template":"elementor_header_footer","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[4],"tags":[],"class_list":["post-519457","post","type-post","status-publish","format-standard","hentry","category-auto-news"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>U0517 Code Symptoms, Causes, Diagnosis &amp; Repair &amp; Reprogramming Guide - Flagship One Blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"U0517 Code Symptoms, Causes, Diagnosis &amp; Repair &amp; Reprogramming Guide - Flagship One Blog\" \/>\n<meta property=\"og:description\" content=\"Door lock\/unlock fails, warning light on vehicle? Invalid data from Door Switch B can shut off BCM functions\u2014scan, test the switch, reprogram or replace.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/\" \/>\n<meta property=\"og:site_name\" content=\"Flagship One Blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/flagshipone\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/flagshipone\/\" \/>\n<meta property=\"article:published_time\" content=\"2025-12-11T16:22:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.fs1inc.com\/blog\/wp-content\/uploads\/2025\/12\/fs1inc_logo2-scaled.jpg\" \/>\n<meta name=\"author\" content=\"FlagshipOne\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@theflagshipone\" \/>\n<meta name=\"twitter:site\" content=\"@theflagshipone\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"FlagshipOne\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/dtc-u0517-invalid-data-received-from-door-switch-b\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/dtc-u0517-invalid-data-received-from-door-switch-b\\\/\"},\"author\":{\"name\":\"FlagshipOne\",\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/#\\\/schema\\\/person\\\/a3cf463514bd03eb7656953ef8f75700\"},\"headline\":\"U0517 Code Symptoms, Causes, Diagnosis &#038; Repair &#038; Reprogramming Guide\",\"datePublished\":\"2025-12-11T16:22:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/dtc-u0517-invalid-data-received-from-door-switch-b\\\/\"},\"wordCount\":1231,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/dtc-u0517-invalid-data-received-from-door-switch-b\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/fs1inc_logo2-scaled.jpg\",\"articleSection\":[\"Auto News\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/dtc-u0517-invalid-data-received-from-door-switch-b\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/dtc-u0517-invalid-data-received-from-door-switch-b\\\/\",\"url\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/dtc-u0517-invalid-data-received-from-door-switch-b\\\/\",\"name\":\"U0517 Code Symptoms, Causes, Diagnosis & Repair & Reprogramming Guide - Flagship One Blog\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/dtc-u0517-invalid-data-received-from-door-switch-b\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/dtc-u0517-invalid-data-received-from-door-switch-b\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/fs1inc_logo2-scaled.jpg\",\"datePublished\":\"2025-12-11T16:22:45+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/dtc-u0517-invalid-data-received-from-door-switch-b\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/dtc-u0517-invalid-data-received-from-door-switch-b\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/dtc-u0517-invalid-data-received-from-door-switch-b\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/fs1inc_logo2-scaled.jpg\",\"contentUrl\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/fs1inc_logo2-scaled.jpg\",\"width\":2560,\"height\":617},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/dtc-u0517-invalid-data-received-from-door-switch-b\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"U0517 Code Symptoms, Causes, Diagnosis &#038; Repair &#038; Reprogramming Guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/\",\"name\":\"Flagship One Blog\",\"description\":\"Flagship One Inc. OEM Engine Computers  Control Modules\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/#organization\",\"name\":\"Flagship One, Inc.\",\"url\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/wp-content\\\/uploads\\\/2019\\\/06\\\/web-lg-fs1-logo.png\",\"contentUrl\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/wp-content\\\/uploads\\\/2019\\\/06\\\/web-lg-fs1-logo.png\",\"width\":1341,\"height\":1098,\"caption\":\"Flagship One, Inc.\"},\"image\":{\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/flagshipone\",\"https:\\\/\\\/x.com\\\/theflagshipone\",\"https:\\\/\\\/www.instagram.com\\\/flagship_one\",\"https:\\\/\\\/www.youtube.com\\\/channel\\\/UC0oyKphffBM2qkJ-gKPmMXw\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/#\\\/schema\\\/person\\\/a3cf463514bd03eb7656953ef8f75700\",\"name\":\"FlagshipOne\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/351b81e51993825aea73280c48061a7205fdd2189730ebbdee5d63894c5cebb4?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/351b81e51993825aea73280c48061a7205fdd2189730ebbdee5d63894c5cebb4?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/351b81e51993825aea73280c48061a7205fdd2189730ebbdee5d63894c5cebb4?s=96&d=mm&r=g\",\"caption\":\"FlagshipOne\"},\"description\":\"The world's top supplier of programmed OEM (Original Equipment Manufacturer) Powertrain Control Modules (PCM), Engine Control Modules (ECM), Injection Control Modules (IDM), Body Control Modules (BCM), Transmission Control Modules (TCM), Engine Control Units and all other car control units. With over a decade in the business, we are the most reliable source when it comes to programming services for replacement engine control modules.\",\"sameAs\":[\"https:\\\/\\\/www.fs1inc.com\\\/\",\"https:\\\/\\\/www.facebook.com\\\/flagshipone\\\/\",\"https:\\\/\\\/www.instagram.com\\\/flagship_one\\\/\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/fs1inc\"],\"url\":\"https:\\\/\\\/www.fs1inc.com\\\/blog\\\/author\\\/flagship1inc\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"U0517 Code Symptoms, Causes, Diagnosis & Repair & Reprogramming Guide - Flagship One Blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/","og_locale":"en_US","og_type":"article","og_title":"U0517 Code Symptoms, Causes, Diagnosis & Repair & Reprogramming Guide - Flagship One Blog","og_description":"Door lock\/unlock fails, warning light on vehicle? Invalid data from Door Switch B can shut off BCM functions\u2014scan, test the switch, reprogram or replace.","og_url":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/","og_site_name":"Flagship One Blog","article_publisher":"https:\/\/www.facebook.com\/flagshipone","article_author":"https:\/\/www.facebook.com\/flagshipone\/","article_published_time":"2025-12-11T16:22:45+00:00","og_image":[{"url":"https:\/\/www.fs1inc.com\/blog\/wp-content\/uploads\/2025\/12\/fs1inc_logo2-scaled.jpg","type":"","width":"","height":""}],"author":"FlagshipOne","twitter_card":"summary_large_image","twitter_creator":"@theflagshipone","twitter_site":"@theflagshipone","twitter_misc":{"Written by":"FlagshipOne","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/#article","isPartOf":{"@id":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/"},"author":{"name":"FlagshipOne","@id":"https:\/\/www.fs1inc.com\/blog\/#\/schema\/person\/a3cf463514bd03eb7656953ef8f75700"},"headline":"U0517 Code Symptoms, Causes, Diagnosis &#038; Repair &#038; Reprogramming Guide","datePublished":"2025-12-11T16:22:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/"},"wordCount":1231,"commentCount":0,"publisher":{"@id":"https:\/\/www.fs1inc.com\/blog\/#organization"},"image":{"@id":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/#primaryimage"},"thumbnailUrl":"https:\/\/www.fs1inc.com\/blog\/wp-content\/uploads\/2025\/12\/fs1inc_logo2-scaled.jpg","articleSection":["Auto News"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/","url":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/","name":"U0517 Code Symptoms, Causes, Diagnosis & Repair & Reprogramming Guide - Flagship One Blog","isPartOf":{"@id":"https:\/\/www.fs1inc.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/#primaryimage"},"image":{"@id":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/#primaryimage"},"thumbnailUrl":"https:\/\/www.fs1inc.com\/blog\/wp-content\/uploads\/2025\/12\/fs1inc_logo2-scaled.jpg","datePublished":"2025-12-11T16:22:45+00:00","breadcrumb":{"@id":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/#primaryimage","url":"https:\/\/www.fs1inc.com\/blog\/wp-content\/uploads\/2025\/12\/fs1inc_logo2-scaled.jpg","contentUrl":"https:\/\/www.fs1inc.com\/blog\/wp-content\/uploads\/2025\/12\/fs1inc_logo2-scaled.jpg","width":2560,"height":617},{"@type":"BreadcrumbList","@id":"https:\/\/www.fs1inc.com\/blog\/dtc-u0517-invalid-data-received-from-door-switch-b\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.fs1inc.com\/blog\/"},{"@type":"ListItem","position":2,"name":"U0517 Code Symptoms, Causes, Diagnosis &#038; Repair &#038; Reprogramming Guide"}]},{"@type":"WebSite","@id":"https:\/\/www.fs1inc.com\/blog\/#website","url":"https:\/\/www.fs1inc.com\/blog\/","name":"Flagship One Blog","description":"Flagship One Inc. OEM Engine Computers  Control Modules","publisher":{"@id":"https:\/\/www.fs1inc.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.fs1inc.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.fs1inc.com\/blog\/#organization","name":"Flagship One, Inc.","url":"https:\/\/www.fs1inc.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.fs1inc.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/www.fs1inc.com\/blog\/wp-content\/uploads\/2019\/06\/web-lg-fs1-logo.png","contentUrl":"https:\/\/www.fs1inc.com\/blog\/wp-content\/uploads\/2019\/06\/web-lg-fs1-logo.png","width":1341,"height":1098,"caption":"Flagship One, Inc."},"image":{"@id":"https:\/\/www.fs1inc.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/flagshipone","https:\/\/x.com\/theflagshipone","https:\/\/www.instagram.com\/flagship_one","https:\/\/www.youtube.com\/channel\/UC0oyKphffBM2qkJ-gKPmMXw"]},{"@type":"Person","@id":"https:\/\/www.fs1inc.com\/blog\/#\/schema\/person\/a3cf463514bd03eb7656953ef8f75700","name":"FlagshipOne","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/351b81e51993825aea73280c48061a7205fdd2189730ebbdee5d63894c5cebb4?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/351b81e51993825aea73280c48061a7205fdd2189730ebbdee5d63894c5cebb4?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/351b81e51993825aea73280c48061a7205fdd2189730ebbdee5d63894c5cebb4?s=96&d=mm&r=g","caption":"FlagshipOne"},"description":"The world's top supplier of programmed OEM (Original Equipment Manufacturer) Powertrain Control Modules (PCM), Engine Control Modules (ECM), Injection Control Modules (IDM), Body Control Modules (BCM), Transmission Control Modules (TCM), Engine Control Units and all other car control units. With over a decade in the business, we are the most reliable source when it comes to programming services for replacement engine control modules.","sameAs":["https:\/\/www.fs1inc.com\/","https:\/\/www.facebook.com\/flagshipone\/","https:\/\/www.instagram.com\/flagship_one\/","https:\/\/www.linkedin.com\/company\/fs1inc"],"url":"https:\/\/www.fs1inc.com\/blog\/author\/flagship1inc\/"}]}},"_links":{"self":[{"href":"https:\/\/www.fs1inc.com\/blog\/wp-json\/wp\/v2\/posts\/519457","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fs1inc.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.fs1inc.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.fs1inc.com\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fs1inc.com\/blog\/wp-json\/wp\/v2\/comments?post=519457"}],"version-history":[{"count":0,"href":"https:\/\/www.fs1inc.com\/blog\/wp-json\/wp\/v2\/posts\/519457\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.fs1inc.com\/blog\/wp-json\/wp\/v2\/media?parent=519457"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.fs1inc.com\/blog\/wp-json\/wp\/v2\/categories?post=519457"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.fs1inc.com\/blog\/wp-json\/wp\/v2\/tags?post=519457"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}